Ampac FireFinder II Series Specifications Page 1

Browse online or download Specifications for Fire protection Ampac FireFinder II Series. Ampac FireFinder II Series Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 87
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
FIREFINDER SERIES II FIRE BRIGADE RESPONSE
GUIDE
Fire Alarm Control Panel
Series II
SE Asia (CP10, MS1404)
Installation, Commissioning &
Operation
MAN 2536-6
FireFinder
Page view 0
1 2 3 4 5 6 ... 86 87

Summary of Contents

Page 1 - FireFinder

FIREFINDER SERIES II FIRE BRIGADE RESPONSE GUIDE Fire Alarm Control Panel Series II SE Asia (CP10, MS1404) Installation, Commissioning &a

Page 2 - INCOMING ALARM CONDITION

Page 5 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 3 FireFinder Description The following description does not relate to s

Page 3

Page 6 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION The FireFinder Series II has an internal ASPI (Ampac Serial Peripheral I

Page 4

Page 7 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION MAIN CPU BOARD27VDC(CN16) INUP TO 3 ADDITIONALSLAVE CPU's (302-6

Page 5

Page 8 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4 Placing The Basic System Into Operation 4.1 Unpacking Carefully unpa

Page 6 - 1 About This Manual

Page 9 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.6 Operational Parameters GENERAL Communication Protocol AMPAC XP95 /

Page 7 - 2 System Overview

Page 10 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.7 Cabling Recommendations Conventional Zones Cabled in red Twin Plas

Page 8 - FUSE BLOCK

Page 11 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.8 Power Supplies and AC Mains Installation Generally the AC Mains wi

Page 9

Page 12 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.8.2 Connecting the Mains Power to the Power Supply 5 AMP Power Suppl

Page 10 - 3 FireFinder Description

Page 13 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.9 Brigade / PSU Monitor Board The Brigade / PSU Monitor Board

Page 11 - OPERATION

Page 14 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION Aux PowerO/PDisable RelayAlarm RelayNO C NC+ -+ -NO C NCBatt Fa

Page 12

FIREFINDER SERIES II FIRE BRIGADE RESPONSE GUIDE DESCRIPTION TYPELOOP No SENSOR No STATUS ALARMDATE TIMESENSOR A

Page 13 - Tap lightly around the

Page 15 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.9.1 Battery Connections (TB1) A FireFinder requires two (2) 12 volt

Page 14 - 4.6 Operational Parameters

Page 16 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.9.4 Relay Output Connections (TB6 – TB10) The relay contacts are con

Page 15 - 4.7 Cabling Recommendations

Page 17 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.10 Main Board The Main Board is the "heart" of the FACP an

Page 16

Page 18 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.11 Front Panel Board The Front Panel Board provides the buttons used

Page 17

Page 19 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.12 Main CPU The Main CPU holds the main central processing unit for

Page 18

Page 20 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.13 Slave CPU The Slave CPU (Central Processing Unit) provides the in

Page 19 - - + -- + -- +

Page 21 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.14 Conventional Zone Board Under the control of a Slave CPU the Conv

Page 20

Page 22 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 4.15 Addressable Loop Termination Board The Addressable Loop Terminati

Page 21

Page 23 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5 Expanding the FACP with Compatible FireFinder Boards 5.1 Ancil

Page 22 - 4.10 Main Board

Page 24 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.2 Expansion Board The Expansion Connection Board is used to increase

Page 23 - 4.11 Front Panel Board

TABLE OF CONTENTS Page No. 1 About This Manual ...

Page 24 - 4.12 Main CPU

Page 25 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.4 16/16 Input / Output Board The Input / Output Board is connected t

Page 25 - 4.13 Slave CPU

Page 26 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.6 16 Way Input Board Opto-Inputs: Up to 16 inputs can be connecte

Page 26

Page 27 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.8 External Control Interface Board The External Control Interface Bo

Page 27

Page 28 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.9 Zone & General Indicator Card The General Indicator Card come

Page 28 - 5.1 Ancillary Services

Page 29 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.10 8 Way Sounder / Bell Monitor Board The 8 way Sounder Monitor Boa

Page 29 - 5.3 Expansion Controller

Page 30 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.11 LED Mimic Board The LED Mimic Board has been designed to

Page 30 - 5.5 8 Way Relay Board

Page 31 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION ON1 2 3 4 5 6

Page 31 - 5.7 Serial Relay Board

Page 32 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION ON1 2 3 4 5 6

Page 32 - 0V 5 6 7 8

Page 33 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.12 High Level Interface Expander Hardware The High Level Interface E

Page 33 - Top OverLay

Page 34 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.13 Communications Extender Board The Communications Extender Board i

Page 34 - All Fuses are 1A M205 Style

5.14.6 SmartTerminal Controls and Indicators ... 40 5.14.7 SMARTTERMINAL Screen Format ...

Page 35 - 5.11 LED Mimic Board

Page 35 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.14 SmartTerminal SmartTerminal connects to the FireFinder Fire

Page 36 - Page 31

Page 36 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.14.2 Mechanical SmartTerminal can be supplied in three variants Slim

Page 37 - Page 32

Page 37 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.14.3 Installation & Cabling The Communications Extender Board

Page 38 - MAIN CONTROL BOARD (BRD85MBA)

Page 38 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.14.4 Setting the Address Open the front door; locate the “CONFIG” bu

Page 39 - FACP MAIN

Page 39 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.14.5 Operation The operation of SmartTerminal can be considered to b

Page 40 - 5.14 SmartTerminal

Page 40 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.14.6 SmartTerminal Controls and Indicators All controls, except for

Page 41 - DOOR RELEASE PINS

Page 41 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION In the event of a loss of communications, for a period of greater than

Page 42 - SHIELDED COMMS CABLE

Page 42 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.14.8 Setting the SmartTerminal Controller Configuration in ConfigMan

Page 43 - 5.14.4 Setting the Address

Page 43 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION In the above example Card 1 & 2;  Are active  Are situated in t

Page 44 - 5.14.5 Operation

Page 44 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.14.11 Specifications MECHANICAL Dimensions ABS Cabinet: ( mm ) 195mm

Page 45

16 Address Setting ... 74 17 Glos

Page 46

Page 45 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.15 Printer Specifications  Printing method: directed impact dot ma

Page 47

Page 46 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION Self-Test Mode With power applied (green LED illuminated) push the SEL

Page 48

Page 47 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION HingesLEDPushButtonsPaperPUSHMechanismReleaseButtonNote:Front DoorRemov

Page 49

Page 48 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 5.15.3 Printer Connections and Jumpering Mounted on the back of the pr

Page 50 - 5.15 Printer

Page 49 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 6 Expanding the System Through Networking Expanding the system can be

Page 51 - Paper Cutter

Page 50 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 2 WIRE & SHIELDRS422 COMMS OUT2 WIRE & SHIELDRS422 COMMS IN27V

Page 52 - Replacement Paper Roll

Page 51 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION SmartTerminalCOMMUNICATIONSEXTENDER BOARD2 WIRE & SHIELDRS422 COMMS

Page 53 - 27VDC IN

Page 52 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 6.2 Conventional Network Board The Conventional Network Board provides

Page 54 -  IMPORTANT

Page 53 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 7 FireFinder Control Panel MENUFUNCTIONPOWER ONPRE-ALARMTEST MODESOUND

Page 55

Page 54 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION PREVIOUS This button is used for scrolling backwards through fire alarm

Page 56

Page 1 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 1 About This Manual 1.1 Introduction This manual contains all the inf

Page 57

Page 55 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION DEVICEDISABLE/ENABLE This button is used to disable or re-enable select

Page 58 - 7 FireFinder Control Panel

Page 56 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION IMPORTANT NOTE: It is strongly recommended that all field programming c

Page 59

Page 57 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 9 The Main Menu The MAIN MENU is accessed by pressing MENU. Figure 60

Page 60 - CANCEL ENTRY

Page 58 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION  Network Note: This option is only available if the system configurat

Page 61 - FUNCTION

Page 59 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION  Is pressed to access SYSTEM STATUS - .For a network panel Figure 65

Page 62 - 9 The Main Menu

Page 60 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 9.2.3 Lamp Test  Is pressed to initiate a Lamp Test: The test will se

Page 63

Page 61 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 10 Main Functions Figure 68: The Level II & III Functions Menu 10

Page 64 - PREVIOUS

Page 62 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION The type of log, number and totals logged, date and time of the ALARM,

Page 65 - 9.2.5 Printer Menu

Page 63 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 10.6 Function Manual I/O Control Press  To display the Manual I/O Con

Page 66

Page 64 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 10.7 Function Access (Level II) / Passwords (Level III) Press  While

Page 67

Page 2 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 2 System Overview The FireFinder Series II is an Intelligent Analogue /

Page 68

Page 65 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 10.8.1 Conventional Zone Programming Press  Zone: Key in the zo

Page 69 - 10.8 Function Programming

Page 66 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION After scrolling through the groups and entering what I/O GROUPS will be

Page 70 -  Zone:

Page 67 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 10.8.4 Output Programming Press  OUTPUT: By following the screen prom

Page 71 -  To EDIT or  to DELETE

Page 68 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 10.8.8 Mismatch Detected If a mismatch is detected the Normal Default

Page 72 -  OUTPUT:

Page 69 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 11 Incoming Fire Alarm Signal  Will operate the red common LED fire

Page 73

Page 70 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 12 Accessing a Loop, Sensor or Zone LOOP OR SENSOR  From the defaul

Page 74

Page 71 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 13 RS232 Modem / Programming / Debug Interfacing The modem I/O port is

Page 75

Page 72 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 14 Certification Information The FireFinder™ is designed and manufactu

Page 76

Page 73 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 15 Troubleshooting Chart Problem Solution No Mains Power Check mains F

Page 77 - HEAD OFFICE

Page 74 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 16 Address Setting BINARY ADDRESS SETTING (AMPAC) SERIES XP95 - ADDRES

Page 78 - 15 Troubleshooting Chart

Page 3 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 2.1 FACP Configuration Examples MAIN CONTROL CARD20 WAY10 WAYFRONT PANE

Page 79 - 16 Address Setting

Page 75 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 17 Glossary of Terms ACF: ANCILLARY CONTROL FACILITY ACKD: ACKNOW

Page 80 - 17 Glossary of Terms

Page 76 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 18 Definitions Addressable system - a fire alarm and detection system

Page 81 - 18 Definitions

Page 77 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 19 Maintenance To ensure continuous reliability of the system, an agre

Page 82 - 19 Maintenance

Page 78 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 19.1.4 Monthly Test In addition to the Weekly Test specified above,

Page 83 - 19.1.4 Monthly Test

Page 79 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 19.1.5 Annual Test The Annual Test should consist of all the inspectio

Page 84 - 19.1.5 Annual Test

Page 80 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION 20 Quick Reference Guides The following guides;  Prompt / assist an

Page 85 - Quick Reference

Page 81 FireFinderTMQuick ReferenceFUNCTION KEY ( TO ENTER FUNCTION FIELD ( ENTER PASSWORD ) )PROG ( PROGRAMMING FEILDS )EDIT ( EDIT DESCRIPTION )DEL

Page 86

NOTES: UNCONTROLLED DOCUMENT NOTE: Due to AMPAC’s commitment to continuous improvement

Page 87

Page 4 FIREFINDER SERIES II INSTALLATION, COMMISSIONING & OPERATION + -+ -+ -AUXI LIAR Y+ B AT -+ IN -DBA/MCPDOOR SWBEL L2BE LL1FAU LTVA

Comments to this Manuals

No comments